NITRILE EXAMINATION POWDER FREE GLOVE

NITRILE EXAMINATION POWDER FREE GLOVE

Category:

Description

Nitrile Examination Glove is used as a good biological & chemical barrier to protect the user’s hands against contamination and dangerous substances. It is the most popular and reliable glove for medical healthcare and dental industries. Made of premium compounded nitrile eliminating latex allergy concern. It comes with excellent fit, comfort, sensitivity and protection. Its textured surface helps to provide secure grip and added handling precision. Proudly available in an extensive selection of colors giving businesses more options.

 

Product Specification

  • Material Synthetic Nitrile Latex
  • TypePowder Free, Non-Sterile
  • Colour Blue, Black, White, Cool Blue, Cornflower Blue, Pink, Light Purple, Green, Orange, Red, Magenta, Yellow(Other colours available upon request)
  • Flavour (If applicable)N/A
  • Design & FeaturesFinger Textured or Palm Textured Surface, Ambidextrous, Beaded cuff, Online Single Chlorinated or Polymer coated
  • StorageThe gloves shall maintain their properties when stored in a dry condition. Avoid direct sunlight.
  • Shelf Life5 years from the date of manufacturing
  • ApplicationMedical,  Healthcare, Dental

Quality Performance

Functional Benefits

  • A good barrier protection against bacteria, viruses, chemicals and dangerous substances
  • An alternative solution for individuals who are allergic to Natural Rubber Latex
  • Free from latex protein, eliminating Type I Immediate Hypersensitivity reaction
  • Custom design enhanced comfort and fit
  • Finger or palm textured enhanced wet and dry grip with added handling precision
  • Chlorinated or polymer powder free interior promote smooth donning & doffing experience

Glove Sizes

  • XS
  • S
  • M
  • L
  • XL
  • XXL

Quality Standards

  • Manufactured under QSR (GMP), ISO 9001:2015 and ISO 13485:2016 Quality Management System
  • Conform to ASTM D6319, EN455, ISO 11193 Standards
  • Complies to PPE Regulation (EU) 2016/425 requirements

Physical Dimension & Physical Properties

TOP GLOVE

Size Length (mm) Palm width (mm) Thickness : Single wall (mm)
  • XS
  • S
  • M
  • L
  • XL
  • XXL
  • Min 230
  • Min 240
  • 300 ± 10
  • 76 ± 3
  • 84 ± 3
  • 94 ± 3
  • 105 ± 3
  • 113 ± 3
  • 123 ±3
  • Finger : Min 0.05 (≥ 2.0 Mil)
  • Palm : Min 0.05 (≥ 2.0 Mil)

ASTM D6319

Size Length (mm) Palm width (mm) Thickness : Single wall (mm)
  • XS
  • S
  • M
  • L
  • XL
  • XXL
  • Min 220 (XS, S)
  • Min 230 (M, L, XL, XXL)
  • 70 ± 10
  • 80 ± 10
  • 95 ± 10
  • 110 ± 10
  • 120 ± 10
  • 130 ± 10
  • Finger: Min 0.05 (≥ 2.0 Mil)
  • Palm :  Min 0.05 (≥ 2.0 Mil)

Elongation at Break, %

  • Before Aging

    Min 500

  • After Aging

    Min 400

Tensile Strength, MPa

  • Before Aging

    Min 14

  • After Aging

    Min 14

EN 455

Size Length (mm) Palm width (mm) Thickness : Single wall (mm)
  • XS
  • S
  • M
  • L
  • XL
  • XXL
  • Min 240
  • ≤80
  • 80 ± 10
  • 95 ± 10
  • 110 ± 10
  • ≥110
  • N/A
  • N/A

Median Force at Break, N

  • Before Aging

    Min 6

  • After Aging

    Min 6

ISO 11193

Size Length (mm) Palm width (mm) Thickness : Single wall (mm)
  • XS
  • S
  • M
  • L
  • XL
  • XXL
  • Min 220 (XS, S)
  • Min 230 (M, L, XL)
  • ≤80
  • 80 ± 10
  • 95 ± 10
  • 110 ± 10
  • ≥110
  • N/A
  • Smooth : Min 0.08 (≥ 3.2 Mil)
  • Textured : Min 0.11 (≥ 4.4 Mil)

Elongation at Break, %

  • Before Aging

    Min 500

  • After Aging

    Min 400

Median Force at Break, N

  • Before Aging

    Min 7

  • After Aging

    Min 6

Product Safety Conformance

CHEMICAL RESIDUE TESTEDPass

Purpose: To ensure the gloves are free from any chemical substances and safe to use.

Chemical Test (s) Test Results (μg/g)
Butylated Hydroxyanisole (BHA) Not Detected
Butylated Hydroxytoluene (BHT) Not Detected
Diphenyl Guanidine (DPG) Not Detected
Diphenyl Thiourea (DPT) Not Detected
Mercaptobenzothiazole (MBT) Not Detected
Tetramethylthiuram Disulphide (TMTD) Not Detected
Zinc Dibutyldithiocarbamate (ZDBC) Not Detected
Zinc Diethyldithiocarbamate (ZDEC) Not Detected
Zinc Dimethyldithiocarbamate (ZDMC) Not Detected
Zinc Mercaptobenzimidazole (ZMBI) Not Detected
Zinc Mercaptobenzothiazole (ZMBT) Not Detected
Zinc Pentamethyleneditithiocarbamate (ZPMC) Not Detected

Remark: Applicable to selected product. Please liaise with our representative for further details.

VIRAL PENETRATION TESTEDPass

Reference: ASTM F1671 – Standard Test Method for Resistance of Materials Used in Protective Clothing to Penetration by Blood – Borne Pathogens Using Phl-X 174 Bacteriophage Penetration as a Test System

Purpose: To test the barrier protection of the gloves from the passages of the viruses.

Viral Penetration Test Results
PASSES

Remark: Applicable to selected products. Please liaise with our representative for further details.

BIOCOMPATIBILITY TESTEDPass

Reference: ISO 10993-10 (Test for Skin Irritation and Skin Sensitization)

Purpose: Biological evaluation for medical devices for irritation and delayed type hypersensitivity.

Biocompatibility Test Test Results
Primary Skin Irritation PASSES

Not a primary skin irritant under condition of the study

Skin Sensitization PASSES

Not a contact sensitizer under condition of the study


Remark: Applicable to selected product. Please liaise with our representative for further details.

HEAVY METAL TESTEDPass

Reference: EPA Method 3052

Purpose: To ensure the gloves are free from heavy metal substances and safe to use.

Chemical Test (s) Test Results (μg/g)
Cadmium (Cd) Not Detected
Lead (Pb) Not Detected
Mercury (Hg) Not Detected
Arsenic (As) Not Detected
Antimony (Sb) Not Detected
Tin (Sm) Not Detected

Remark: Applicable to selected product. Please liaise with our representative for further details.

PHTHALATES TESTEDPass

Purpose: Compliance on REACH Regulation (EC) 1907/2006 Annex XVII requirements for phthalates

Chemical Test (s) Test Results (μg/g)
Dibutyl Phthalate (DBP) Not Detected
Di(2-ethylhexyl) Phthalate (DEHP) Not Detected
Di-n-octyl Phthalate (DNOP) Not Detected
Di-isononyl Phthalate (DINP) Not Detected
Di-isodecyl Phthalate (DIDP) Not Detected
Benzyl butyl Phthalate (BBP) Not Detected

 


Remark: Applicable to selected product. Please liaise with our representative for further details.